SDPA- MODES
Working Modes Of SDPA-3
Mode:- 1. Solar to Battery charging

- Solar to battery charging
- Solar Power ON
- Load OFF or disconnected
- E1 shows charging efficiency.
Mode:- 2. Solar to Battery charging & Load ON

- Solar to battery charging & also Load ON
- Solar supply power to battery and load both.
- E1 shows battery charging efficiency
- E2 shows battery to load efficiency.
- E3 shows load efficiency with solar + battery
Mode:- 3. Solar and Battery supply power to Load

- Solar and battery both supply power to Load ON
- Solar ON and Battery discharge
- E1 shows battery to solar efficiency
- E2 shows battery to load efficiency.
- E3 shows load efficiency with solar + battery
Mode:- 4. Battery to Load
.png)
- Solar OFF or disconnected
- Battery power supply to the load
- E2 shows battery to load efficiency.
Mode:- 5. Solar to Load

- Solar power to load
- Solar power supply to the load
- E3 shows solar to load efficiency.
Mode:- 6. Battery Discharge when Solar & Load both OFF

- Battery Connected and solar & load OFF
- Battery discharge due to driver power consumption
Mode:- 7. All are OFF

- All are disconnected with meter
Mode:- 8. Error

- The error shows when Terminal Connection not proper
- Modes show an error when condition not match