+91-7524853539 Factory: H-54 Bindayaka Industrial Area, Jaipur, Rajasthan, INDIA 302021Email address (shown as a picture to avoid spam)
Home › Products › Transformer Testing › Compact-3 › Knowledgebase
Compact-3 - product photo

Compact-3

Model: Compact-3

Three phase portable turns ratio instrument with 18 vector groups.

Transformer Testing

Knowledgebase

Articles

Vector groups explained: testing all 18 with Compact-3
What a transformer vector group is, how to read the clock number, and how to test all 18 vector groups (Dd, Dyn, YNd, YNyn, PH) with Compact-3.

Testing of YNyn0 (Yy0) made simple using Compact-3
YNyn0 (Yy0) transformer test with Compact-3: three steps (rn/RN, yn/YN, bn/BN), correct reading +. Connections, photos, software screens.

How to test a YNyn6 (Yy6) transformer with Compact-3
YNyn6 (Yy6) transformer test with Compact-3: three steps (rn/RN, yn/YN, bn/BN), correct reading −. Connections, photos, software screens.

PH0 (single phase) vector group test: steps and expected reading
PH0 (single phase) transformer test with Compact-3: one test (rn/RN), correct reading +. Connections, photos, software screens.

Want to test PH6 (single phase) transformers? Use Compact-3
PH6 (single phase) transformer test with Compact-3: one test (rn/RN), correct reading −. Connections, photos, software screens.

Dd0 transformer test: connections and reading
Dd0 transformer test with Compact-3: three steps (ry/RY, yb/YB, br/BR), correct reading +. Connections, photos, software screens.

Testing of Dd6 made simple using Compact-3
Dd6 transformer test with Compact-3: three steps (ry/RY, yb/YB, br/BR), correct reading −. Connections, photos, software screens.

How to test a Dd2 transformer with Compact-3
Dd2 transformer test with Compact-3: three steps (ry/BR, yb/RY, br/YB), correct reading −. Connections, photos, software screens.

Dd8 vector group test: steps and expected reading
Dd8 transformer test with Compact-3: three steps (ry/BR, yb/RY, br/YB), correct reading +. Connections, photos, software screens.

Want to test Dd4 transformers? Use Compact-3
Dd4 transformer test with Compact-3: three steps (ry/YB, yb/BR, br/RY), correct reading +. Connections, photos, software screens.

Dd10 transformer test: connections and reading
Dd10 transformer test with Compact-3: three steps (ry/YB, yb/BR, br/RY), correct reading −. Connections, photos, software screens.

Testing of YNd1 made simple using Compact-3
YNd1 transformer test with Compact-3: three steps (ry/RN, yb/YN, br/BN), correct reading +. Connections, photos, software screens.

How to test a YNd7 transformer with Compact-3
YNd7 transformer test with Compact-3: three steps (ry/RN, yb/YN, br/BN), correct reading −. Connections, photos, software screens.

YNd11 vector group test: steps and expected reading
YNd11 transformer test with Compact-3: three steps (ry/YN, yb/BN, br/RN), correct reading −. Connections, photos, software screens.

Want to test YNd5 transformers? Use Compact-3
YNd5 transformer test with Compact-3: three steps (ry/YN, yb/BN, br/RN), correct reading +. Connections, photos, software screens.

Dyn11 transformer test: connections and reading
Dyn11 transformer test with Compact-3: three steps (rn/RY, yn/YB, bn/BR), correct reading +. Connections, photos, software screens.

Testing of Dyn5 made simple using Compact-3
Dyn5 transformer test with Compact-3: three steps (rn/RY, yn/YB, bn/BR), correct reading −. Connections, photos, software screens.

How to test a Dyn7 transformer with Compact-3
Dyn7 transformer test with Compact-3: three steps (rn/BR, yn/RY, bn/YB), correct reading +. Connections, photos, software screens.

Dyn1 vector group test: steps and expected reading
Dyn1 transformer test with Compact-3: three steps (rn/BR, yn/RY, bn/YB), correct reading −. Connections, photos, software screens.